Skip to main content
Skip table of contents

FactoryLogix default port settings

ADMINISTRATOR

The following table lists the default port settings used by the FactoryLogix system.

Port 

Protocol 

Description

Where used

25

SMTP

SMTP Server

The default port used by the SMTP server when sending emails in FactoryLogix.

You can change this port in NPI (Settings > Global Options > General > Option Type: E-Mail).

808 

TCP 

FactoryLogix License Server 

The default port used by the FactoryLogix License Server (the computer that hosts your license information).

This port is used by clients to pull licensing information/validation from the FactoryLogix Application Service.

1433 

TCP 

Microsoft SQL Server 

The port used by your SQL Server.

1883

TCP

inForce 2.0

This port is used for MQTT communications used by inForce 2.0

3702 

UDP 

FactoryLogix Application Service

The default port used by clients to leverage Windows Network Discovery and find/discover available Application Services to connect to. (It’s not needed but recommended—if it’s not configured, you must enter the server connection settings manually.)

6060 

TCP 

FactoryLogix Real Time Analysis Service 

The default port used for communication between the FactoryLogix Real-Time Server and clients.

This port needs to be open between the server running the Real Time Analysis Service and any clients that connect to it so clients can access the data pushed by the service (NPI, Production, and iMonitor dashboards, for example).

You can change this port in NPI (Settings > Global Options > Real-Time Analysis > Option Type: Real-Time Analysis - Settings > Server Port).

6062 

TCP 

FactoryLogix inSite Mobile App & Mobile Logistics 

The default port used by the server running the FactoryLogix Application Service for Using Mobile Logistics and inSite clients.

6063 

TCP 

FactoryLogix xTend API Service

The default port used for API calls to/from customer applications and for the FactoryLogix xTend API Service.

6064 

TCP 

FactoryLogix Archive Service 

The default port for the Archive Server (the computer that hosts the FactoryLogix Archive Service).

7000 

TCP 

inForce 1.0 and 2.0

This port needs to be open between inForce 1.0 and the xLink Server

8000 

TCP 

inForce 1.0 and 2.0

This port needs to be open between inForce 1.0 and the xLink Server

8888

UDP

inForce 2.0

This port is used for the "discovery" of new inForce 2.0 units.  It utilizes a UDP datagram.

8393 

TCP 

V7 License Server 

The default port used by the V7 License Server (the computer that hosts your license information).

This port is used by clients to pull licensing information/validation from the V7 Application Service.